REVO NX 130

Optopol engineering team, designers of the first commercially available Spectral Domain OCT in the World, is proud to present the World’s fastest OCT.

Optopol engineering team, the designers of the firstcommercially available Spectral Domain OCT in the world, are proud to present the latest innovation, the world`s first B-OCT and T-OCT for standard
posterior OCT. Our supreme experience in Spectral Domain OCT allows us to provide the market with a state of the art instrument which comes with new advanced technologies and remarkable simplicity of operation.

Overview
New OCT standard - All functionality In One device.
Once again Revo NX goes beyond the limits of standard OCT. With its new scanning speed, our Revo NX 130 enables a full functionality scanning from the retina to the cornea. It brings benef ts by combining the potential of several devices. With REVO you can measure, quantify, calculate and track changes from the cornea to the retina over time with just one OCT device.

i Tracking™
iTracking™ technology compensates involuntary eye movements and blinks. When OCT scan is used each anatomical region is acquired twice automatically. The system immediately creates an artifactfree MC examination using the Motion Correction TechnologyTM. The elimination of eye movement and blinking artifacts ensures the highest resolution of Angio OCT images without patient inconvenience. Clear OCTA data set allows easier interpret retina vasculature condition.


RETINA

Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans. Software automatically recognize 8  retina layers. Thus allowing a more precise diagnosis and mapping any changes in the patient’s retina condition.
 
Single
 Both
 
Comparison
 Progression
 

OCT Angiography
This optional software module allows visualization of the retinal microvasculature. Angiography SOCT is a non-invasive, dye-free technique providing 3D image of retinal blood circulation.
 
Software allows to observe, track and compare changes in the microvasculature of the retina in both eyes.
 
Standard Single View Detailed Single View
OCT Angiography Standard Single View	  OCT Angiography Detailed Single View
Both View  
OCT Angiography Both View  
Comparison View Progression View
OCT Angiography Comparison View OCT Angiography Progression View

QUANTYFICATION TOOLS: FAZ, VFA
FAZ – Foveal Avascular Zone measurements allow to quantify and monitor changes in Superficial and Deep vascular layer.  FAZ tool is also available for narrow and wide scans.
OCT Angiography FAZ – Foveal Avascular Zone   OCT Angiography FAZ – Foveal Avascular Zone
  Area [mm2]: 0,48

VFA – Vascular Flow Area allows to examine the pathologically affected area and precisely measure the area covered by vascu-larization. User can easily measure area on predefined or own selected vascular layer.
OCT Angiography VFA – Vascular Flow Area  OCT Angiography VFA – Vascular Flow Area
  Area [mm2]: 13,45
Flow area [mm2]:   2,85


ANGIO MOSAIC
The Angiography mosaic delivers high-detailed images over large field of the retina.
Advanced tab provides: view of any vascular layers, enface view of vascular layers, depth coded and thickness map. Mosaic modes: 10x6 mm, 12x5 mm, 7x7 mm, 10x10 mm and Manual (up to 12 images).
 
Mosaic modes: 10x10 mm
 Mosaic modes: 7x7 mm
 
Mosaic modes: 10x6 mm
 Manual (up to 12 images)
 
Mosaic modes: 12x5 mm
 Mosaic modes: 12x5 mm - RPC Enface view
 
Mosaic modes: 12x5 mm -
NFL Thickness map
 Mosaic modes: 12x5 mm -
 Retina Thickness map
 

GLAUCOMA
Comprehensive glaucoma analytical tools for quantification of the Nerve Fiber Layer, Ganglion layer and Optic Head with DDLS allow for the precise diagnosis and monitoring of glaucoma over time.
With the golden standard 14 optic nerve parameters and a new Rim to Disc and Rim Absence the description of ONH condition is quick and precise.
Advanced view which provides combined information from Retina and Disc scan to integrate details of the Ganglion cells, RNFL, ONH in a wide field perspective for comprehensive analysis.

Advance Retina & ONH

ONH Single
GLAUCOMA Advance Retina & ONH  GLAUCOMA ONH Single

Asymmetry Analysis of Ganglion layers between hemi-spheres and between eyes allows easier identification and detection of glaucoma in early stages and in non-typical patients.

Ganglion Both

Ganglion Progression
GLAUCOMA Ganglion Both  GLAUCOMA Ganglion Progression

Implemented the DDLS  - Disc Damage Likelihood Scale which use 3 separate classification for small, average and large discs. It supports the practitioners in a quick and precise evaluation of the patient’s glaucomatous disc damages.

ONH Both

ONH Progression
GLAUCOMA ONH Both  GLAUCOMA ONH Progression

COMPLET YOUR GLAUCOMA REPORT
To eliminate common problem with the understanding of the patient’s IOP pachymetry module provides IOP Correction value.  With the implemented Adjusted IOP formula you can quickly and precisely understand the measured IOP value.  
As the Pachymetry and Anterior Chamber Angle Verification require no additional attachments, the predefined Glaucoma protocol, which consists of Retina, Disc and Anterior scans, can be done automatically to reduce patient chair time.

Closing angle

Anterior single view
Closing angle  Anterior single view
  * Images courtesy of Prof. Edward Wylęgała MD, PhD


ANTERIOR
For standard examinations no additional lens is required.  Additional adapter provided with the device allows to make wide scans of anterior segment.

Cornea single 

Cornea both
ANTERIOR Cornea single   ANTERIOR Cornea both
Cornea Comparison Cornea Progression
Anterior Cornea Comparison Anterior Cornea Progression


BIOMETRY OCT is optional software module to purchase
B-OCT™ innovative method of using the  posterior OCT device to measure ocular structure along eye axis .
OCT Biometry provides complete set of Biometry parameters: Axial Length AL, Central Cornea Thickness CCT, Anterior Chamber Depth ACD, Lens Thickness LT.

Result review
 
Analysis window
 
Visually verify your measurement
All measurement calipers are shown on the all boundaries OCT image provided by REVO. Now, you can visually verify and correct what structure of the eye has been measured.

TOPOGRAPHY OCT is optional software module to purchase
T-OCT™ is a pioneering way to provide detailed corneal Curvature maps by using posterior dedicated OCT. Ante-rior, Posterior  surface and Corneal Thickness allow to provide the  True Net Curvature information. With Net power, the precise understading of the patient’s corneal condition comes easily and is free of errors associated with modelling of posterior surface of the cornea.  SOCT T-OCT module provides Axial maps, Tangential maps, Total Power map, Height maps, Epithelium and Corneal thickness maps.
Corneal topography module clearly shows the changes in the cornea on the difference map view. Customize your
Topography module provides:
  • Full featured Corneal mapping of Anterior, Posterior and Real
  • Precise Astigmatism Display Option (SimK: Anterior, Posterior, Real,  Meridian and Emi-Meridian ø 3, 5, 7 mm zones
KERATOCONUS SCREENING
Easly detect and classified keratoconus with Keratoconus classifier. Classification based on KPI, SAI, DSI, OSI and CSI. In the early stages of kera-toconus the results can be complemented by Epithelium and Pachymatery maps.

Normal

Astigmatysm

Keratoconus
KERATOCONUS SCREENING  KERATOCONUS SCREENING  KERATOCONUS SCREENING

COMPARE THE EXAMS
Comprehensive software features  a range of selectable views: Single, Both. See details on standard Singe view and easly see corneal asymmetry on the Both view.
The follow-up feature in to the T-OCT™ module, allows fully compare the changes in the corneal topography over time for:
  • LASIK undergone patients
  • Keratoconus patients
  • The contact lens wearers
Single Both
TOPOGRAPHY OCT SINGLE  TOPOGRAPHY OCT BOTH
Comparison Progression
TOPOGRAPHY OCT COMPARISON TOPOGRAPHY OCT PROGRESSION


FOLLOW UP
High density of standard 3D scan allows to precisely track the disease progress. Operator can analyze changes is morphology,  quantified progression maps or evaluate the progression trends. 
 
Progression Morphology  Progression Quantification
FOLLOW UP Progression Morphology	  FOLLOW UP Progression Quantification


COMPARISON
Comparison view allows in easy and convince way to review results from two visits. The view is available for most of the scan programs. 
  

NETWORKING
A proficient networking solution increases productivity and an enhanced patient experience. It allows you to view and manipulate multiple examinations from review stations in your practice. Effortlessly helping to facilitate patient education by allowing you to interactively show examination results to patients. Every practice will have differing requirements which we can provide by tailoring a bespoke service. There is no additional charge for the server module.

DICOM
Store, exchange, and transmit results through DICOM gateway to the hospital network. 
 
CNV BRVO
 

ENHANCE TOMOGRAMS - 2 µm Ultra High (Digital) Resolution
 

CHOROID VISUALIZATION
 

CLINICAL IMAGES
  
  
 

CORNEA SCAN

 
Wide cornea scan, Descemet’s membrane detachment (DMD) and iridocorneal adhesions

Wide cornea scan, Descemet’s membrane detachment (DMD) and iridocorneal adhesions
* Images courtesy of Prof. Edward Wylęgała MD, PhD

ANTERIOR

Anterior scan, Cornea Guttata with corneal scaring
Anterior scan, Cornea Guttata with corneal scaring

* Images courtesy of Prof. Edward Wylęgała MD, PhD

ANGIOGRAPHY
  
  

PDR,  Angio Mosaic mode: 10x10 mm
PDR,  Angio Mosaic mode 10x10 mm
*Images courtesy of Bartosz L. Sikorski MD, PhD

ANGLE TO ANGLE ANALYSIS

Angle to Angle scan, narrow angles
Angle to Angle scan, narrow angles
*Image courtesy of Bartosz L. Sikorski MD, PhD
 
Tech specs
Technology Spectral Domain OCT
Scanning speed 130 000 A-scan/sec
Light Source SLED, Wavelength 830nm
Bandwidth 50 nm half bandwidth
Axial resolution 5 μm in tissue
~2,6 μm digital
Transverse Resolution 12 μm, typical 18 μm
Overall scan depth 2.4 mm
Scan range Posterior 5-12 mm, Anterior 3-16mm
Scan types 3D, Angio, Radial HD, B-scan, Raster, Cross HD
Fundus image Live Fundus Reconstruction
Alignment method Fully automatic, Automatic
Retina analysis Retina thickness, Inner retinal thickness, Outer retinal thickness
RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness
RPE deformation, IS/OS thickness
Angiography OCT
an optional software module to purchase
Angiography mosaic
 
Superficial plexus, Deep Plexus, Outer Retina, Choriocapilaries
Depth Coded, Custom, Enface, Thickness
Acquistion method: Auto, Manual
Mosaic modes: 7x7 mm, 10x6 mm, 10x10 mm, 12x5 mm, manual up to 12 images
Glaucoma analysis RNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, OU and Hemisphere asymmetry
Anterior Pachymetry, LASIK flap, Angle Assessment, AIOP, AOD 500/750,
TISA 500/750
Biometry OCT
an optional software module to purchase
AL, CCT, ACD, LT
Corneal Topography Map
an optional software module to purchase
Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height
Connectivity DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking
Anterior Wide Scan Angle to Angle view, Adapter required
Min.  pupil size 3 mm
Focus adjustment range -25D to +25D
Dimensions (WxDxH) 382 x 556 × 469 mm
Weight 23 kg
Fixation target OLED display (The target shape and position can be changed),
External fixation arm
Power supply 110-230 V,  60/50 Hz
Power consumption 115 - 140 VA

 
Find your Distributor

Find your Distributor

Contact Us

Contact Us